MCSE, Novell, A+, Network+  Study CDs And  Cassettes
MCSE, CCNA,  A+, Novell, and ASE Exam Audio CDs
& Certification Study Products & Resources

 



SCSI Internal (Single-ended)

SCSI=Small Computer System Interface.
Based on an original design by Shugart Associates. SCSI was ratified in 1986.


(At the controller & harddisk)

(At the cable)

50 PIN IDC MALE at the controller & harddisk.
50 PIN IDC FEMALE at the cable.
 
Pin
Name
Dir
Description
2
DB0
< >
Data Bus 0
4
DB1
< >
Data Bus 1
6
DB2
< >
Data Bus 2
8
DB3
< >
Data Bus 3
10
DB4
< >
Data Bus 4
12
DB5
< >
Data Bus 5
14
DB6
< >
Data Bus 6
16
DB7
< >
Data Bus 7
18
PARITY
< >
Data Parity (odd Parity)
20
GND
------
Ground
22
GND
------
Ground
24
GND
------
Ground
26
TMPWR
< >
Termination Power
28
GND
------
Ground
30
GND
------
Ground
32
/ATN
<
Attention
34
GND
------
Ground
36
/BSY
< >
Busy
38
/ACK
<
Acknowledge
40
/RST
< >
Reset
42
/MSG
>
Message
44
/SEL
< >
Select
46
/C/D
>
Control/Data
48
/REQ
>
Request
50
/I/O
>
Input/Output


SCSI Internal (Differential)


      (at the controller & harddisk.)                                                   (At the cable)

50 PIN IDC MALE at the controller & harddisk.
50 PIN IDC FEMALE at the cable.
 
Pin
Name
Dir
Description
01
GND
------
Ground
02
GND
------
Ground
03
+DB0
< >
+Data Bus 0
04
-DB0
< >
-Data Bus 0
05
+DB1
< >
+Data Bus 1
06
-DB1
< >
-Data Bus 1
07
+DB2
< >
+Data Bus 2
08
-DB2
< >
-Data Bus 2
09
+DB3
< >
+Data Bus 3
10
-DB3
< >
-Data Bus 3
11
+DB4
< >
+Data Bus 4
12
-DB4
< >
-Data Bus 4
13
+DB5
< >
+Data Bus 5
14
-DB5
< >
-Data Bus 5
15
+DB6
< >
+Data Bus 6
16
-DB6
< >
-Data Bus 6
17
+DB7
< >
+Data Bus 7
18
-DB7
< >
-Data Bus Parity7
19
+DBP
< >
+Data Bus Parity (odd Parity)
20
-DBP
< >
-Data Bus Parity (odd Parity)
21
DIFFSENS
?
???
22
GND
------
Ground
23
res
-
Reserved
24
res
-
Reserved
25
TERMPWR
< >
Termination Power
26
TERMPWR
< >
Termination Power
27
res
-
Reserved
28
res
-
Reserved
29
+ATN
<
+Attention
30
-ATN
<
-Attention
31
GND
------
Ground
32
GND
------
Ground
33
+BSY
< >
+Bus is busy
34
-BSY
< >
-Bus is busy
35
+ACK
<
+Acknowledge
36
-ACK
<
-Acknowledge
37
+RST
< >
+Reset
38
-RST
< >
-Reset
39
+MSG
>
+Message
40
-MSG
>
-Message
41
+SEL
< >
+Select
42
-SEL
< >
-Select
43
+C/D
>
+Control or Data
44
-C/D
>
-Control or Data
45
+REQ
>
+Request
46
-REQ
>
-Request
47
+I/O
>
+In/Out
48
-I/O
>
-In/Out
49
GND
------
Ground
50
GND
------
Ground



 

SCSI-II External Hi D-Sub (Single-ended)

(At the controller & devices).
 

(To the cable)

50 PIN HI-DENSITY D-SUB FEMALE at the controller & devices.
50 PIN HI-DENSITY D-SUB MALE at the cable.
 
Pin
Name
Dir
Description
1-25
GND
------
Ground
26
DB0
< >
Data Bus 0
27
DB1
< >
Data Bus 1
28
DB2
< >
Data Bus 2
29
DB3
< >
Data Bus 3
30
DB4
< >
Data Bus 4
31
DB5
< >
Data Bus 5
32
DB6
< >
Data Bus 6
33
DB7
< >
Data Bus 7
34
PARITY
< >
Data Parity (odd Parity)
35
GND
------
Ground
36
GND
------
Ground
37
GND
------
Ground
38
TMPWR
< >
Termination Power
39
GND
------
Ground
40
GND
------
Ground
41
/ATN
<
Attention
42
n/c
-
Not connected
43
/BSY
< >
Busy
44
/ACK
<
Acknowledge
45
/RST
< >
Reset
46
/MSG
>
Message
47
/SEL
< >
Select
48
/C/D
>
Control/Data
49
/REQ
>
Request
50
/I/O
>
Input/Output

 

SCSI-II External Hi D-Sub (Differential)

(At the controller & devices)


(To the cable)

50 PIN HI-DENSITY D-SUB FEMALE at the controller & devices.
50 PIN HI-DENSITY D-SUB MALE at the cable.
 
Pin
Name
Dir
Description
01
GND
-----
Ground
02
+DB0
< >
+Data Bus 0
03
+DB1
< >
+Data Bus 1
04
+DB2
< >
+Data Bus 2
05
+DB3
< >
+Data Bus 3
06
+DB4
< >
+Data Bus 4
07
+DB5
< >
+Data Bus 5
08
+DB6
< >
+Data Bus 6
09
+DB7
< >
+Data Bus 7
10
+DBP
< >
+Data Bus Parity (odd Parity)
11
DIFFSENS
?
???
12
res
-
Reserved
13
TERMPWR
< >
Termination Power
14
res
-
Reserved
15
+ATN
<
+Attention
16
GND
-----
Ground
17
+BSY
< >
+Bus is busy
18
+ACK
<
+Acknowledge
19
+RST
< >
+Reset
20
+MSG
>
+Message
21
+SEL
< >
+Select
22
+C/D
>
+Control or Data
23
+REQ
>
+Request
24
+I/O
>
+In/Out
25
GND
-----
Ground
26
GND
-----
Ground
27
-DB0
< >
-Data Bus 0
28
-DB1
< >
-Data Bus 1
29
-DB2
< >
-Data Bus 2
30
-DB3
< >
-Data Bus 3
31
-DB4
< >
-Data Bus 4
32
-DB5
< >
-Data Bus 5
33
-DB6
< >
-Data Bus 6
34
-DB7
< >
-Data Bus Parity7
35
-DBP
< >
-Data Bus Parity (odd Parity)
36
GND
-----
Ground
37
res
-
Reserved
38
TERMPWR
< >
Termination Power
39
res
-
Reserved
40
-ATN
<
-Attention
41
GND
-----
Ground
42
-BSY
< >
-Bus is busy
43
-ACK
<
-Acknowledge
44
-RST
< >
-Reset
45
-MSG
>
-Message
46
-SEL
< >
-Select
47
-C/D
>
-Control or Data
48
-REQ
>
-Request
49
-I/O
>
-In/Out
50
GND
-----
Ground



 

SCSI External D-Sub (PC/Amiga/Mac)

(At the controller)


At (the cable)
25 PIN D-SUB FEMALE at the controller.
25 PIN D-SUB MALE at the cable.
 
Pin
Name
Dir
Description
1
/REQ
>
Request
2
/MSG
>
Message
3
I/O
>
Input/Output
4
/RST
< >
Reset
5
/ACK
<
Acknowledge
6
BSY
< >
Busy
7
GND
-----
Ground
8
DB0
< >
Data Bus 0
9
GND
-----
Ground
10
DB3
< >
Data Bus 3
11
DB5
< >
Data Bus 5
12
DB6
< >
Data Bus 6
13
DB7
< >
Data Bus 7
14
GND
-----
Ground
15
C/D
>
Control/Data
16
GND
-----
Ground
17
/ATN
<
Attention
18
GND
-----
Ground
19
/SEL
< >
Select
20
PARITY
< >
Data Parity
21
DB1
< >
Data Bus 1
22
DB2
< >
Data Bus 2
23
DB4
< >
Data Bus 4
24
GND
-----
Ground
25
TMPWR
< >
Termination Power


SCSI External D-Sub (Future Domain)

Seems to be available on some Future Domain SCSI-controllers only.

(At the controller)

(At the cable)

25 PIN D-SUB FEMALE at the controller.
25 PIN D-SUB MALE at the cable.
 
Pin
Name
Dir
Description
1
GND
-----
Ground
2
DB1
< >
Data Bus 1
3
DB3
< >
Data Bus 3
4
DB5
< >
Data Bus 5
5
DB7
< >
Data Bus 7
6
GND
-----
Ground
7
/SEL
< >
Select
8
GND
-----
Ground
9
TMPWR
< >
Termination Power
10
/RST
< >
Reset
11
C/D
>
Control/Data
12
I/O
>
Input/Output
13
GND
-----
Ground
14
DB0
< >
Data Bus 0
15
DB2
< >
Data Bus 2